<codeBook xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xsd="http://www.w3.org/2001/XMLSchema" xsi:schemaLocation="ddi:codebook:2_5 http://www.ddialliance.org/Specification/DDI-Codebook/2.5/XMLSchema/codebook.xsd" xmlns="ddi:codebook:2_5">
  <docDscr>
    <citation>
      <titlStmt>
        <titl xml:lang="sv">Measured heat transfer for thin wires in air</titl>
        <parTitl xml:lang="en">Measured heat transfer for thin wires in air</parTitl>
        <IDNo agency="SND">2025-330-1</IDNo>
        <IDNo agency="DOI">https://doi.org/10.5878/28sr-1k88</IDNo>
      </titlStmt>
      <prodStmt>
        <producer xml:lang="en" abbr="SND">Swedish National Data Service</producer>
        <producer xml:lang="sv" abbr="SND">Svensk nationell datatjänst</producer>
      </prodStmt>
      <holdings URI="https://doi.org/10.5878/28sr-1k88">Landing page</holdings>
    </citation>
  </docDscr>
  <stdyDscr>
    <citation>
      <titlStmt>
        <titl xml:lang="sv">Measured heat transfer for thin wires in air</titl>
        <parTitl xml:lang="en">Measured heat transfer for thin wires in air</parTitl>
        <IDNo agency="SND">2025-330-1</IDNo>
        <IDNo agency="DOI">https://doi.org/10.5878/28sr-1k88</IDNo>
        <IDNo agency="DOI">10.1016/j.expthermflusci.2021.110403</IDNo>
      </titlStmt>
      <rspStmt>
        <AuthEnty xml:lang="en" affiliation="University of Gävle">Lundström, Hans</AuthEnty>
        <AuthEnty xml:lang="sv" affiliation="Högskolan i Gävle">Lundström, Hans</AuthEnty>
      </rspStmt>
      <prodStmt />
      <distStmt>
        <distrbtr xml:lang="en" abbr="SND" URI="https://snd.se">Swedish National Data Service</distrbtr>
        <distrbtr xml:lang="sv" abbr="SND" URI="https://snd.se">Svensk nationell datatjänst</distrbtr>
        <distDate xml:lang="en" date="2025-11-26" />
      </distStmt>
      <verStmt>
        <version elementVersion="1" elementVersionDate="2025-11-26" />
      </verStmt>
      <holdings URI="https://doi.org/10.5878/28sr-1k88">Landing page</holdings>
    </citation>
    <stdyInfo>
      <subject />
      <abstract xml:lang="en" contentType="abstract">Measurements of heat transfer from a heated wire in an streaming air. The measurements were carried out as part of an investigation into hot-wire anemometers. The wires used were made of platinum-plated tungsten with diameters of 5 µm and 2.5 µm.  A range of data sets is presented, covering air temperatures from 10 to 50 °C, velocities from 0.3 to 30 m/s and wire temperatures from 20 to 70°C, though not all data sets span the entire range.</abstract>
      <abstract xml:lang="sv" contentType="abstract">Mätning av värmeöverföring från varmtråd i strömmande luft. Mätningar utförda på trådar av platinabelagd volfram av diameter 2.5 och 5 µm i lufthastigheter 0.3 till 30 m/s, lufttemperaturer 10–50 °C och trådtemperaturer i spannet 20 till 70 °C. Olika mätserier presenteras, alla täcker inte hela hastighets- och temperaturspannet. Uppmätta data har använts för studium av varmtrådsanemometrar.</abstract>
      <sumDscr>
        <dataKind xml:lang="en">Text</dataKind>
      </sumDscr>
    </stdyInfo>
    <method>
      <dataColl>
        <collMode xml:lang="en">The  wire under investigation was mounted between supporting prongs and connected to a variable power supply via a series resistor and a current shunt resistor. The voltages across the wire and the shunt resistor were measured using a Keysight 3497A data acquisition unit and LabVIEW software. The wire resistance and heat dissipation rate were calculated. The wire temperature was determined from the resistance using calibrated data. For selected values of wind tunnel temperature and velocity, the current flowing through the wire was manually adjusted to reach a desired sensor temperature.  Using this method, a data map was compiled across various air velocities, air temperatures, and wire temperatures. From this map, data for different operating conditions of a hot wire sensor can be assembled. For example, collecting measurement points with equal wire temperature reveals the behaviour of the sensor wire as a constant temperature anemometer.<concept vocab="DDI Mode of Collection" vocabURI="https://vocabularies.cessda.eu/v2/vocabularies/ModeOfCollection/5.0.0?languageVersion=en-5.0.0">The  wire under investigation was mounted between supporting prongs and connected to a variable power supply via a series resistor and a current shunt resistor. The voltages across the wire and the shunt resistor were measured using a Keysight 3497A data acquisition unit and LabVIEW software. The wire resistance and heat dissipation rate were calculated. The wire temperature was determined from the resistance using calibrated data. For selected values of wind tunnel temperature and velocity, the current flowing through the wire was manually adjusted to reach a desired sensor temperature.  Using this method, a data map was compiled across various air velocities, air temperatures, and wire temperatures. From this map, data for different operating conditions of a hot wire sensor can be assembled. For example, collecting measurement points with equal wire temperature reveals the behaviour of the sensor wire as a constant temperature anemometer.</concept></collMode>
        <collMode xml:lang="sv">Tråden var monterad mellan stödpinnar av 0.6mm pianotråd och ansluten till en variabel spänningskälla via ett seriemotstånd och ett shuntmotstånd. Spänningarna över tråden och shuntmotståndet mättes med hjälp av en Keysight 3497A datainsamlingsenhet och LabVIEW-programvara. Trådens resistans och tillförd elektrisk effekt (=bortförd värmeeffekt) beräknades. Trådens temperatur bestämdes från resistansen med hjälp av kalibrerade data. För givna värden på  lufthastighet och lufttemperatur justerades den variabla spänningskällan manuellt så att önskad trådtemperatur erhölls för varje mätfall. På detta sätt skapades en tabell med mätdata för olika hastigheter, olika trådtemperaturer och lufttemperaturer. Dessa data kan användas för att studera olika driftfall för en varmtrådsanemometer.<concept vocab="DDI Mode of Collection" vocabURI="https://vocabularies.cessda.eu/v2/vocabularies/ModeOfCollection/5.0.0?languageVersion=sv-5.0.0">Tråden var monterad mellan stödpinnar av 0.6mm pianotråd och ansluten till en variabel spänningskälla via ett seriemotstånd och ett shuntmotstånd. Spänningarna över tråden och shuntmotståndet mättes med hjälp av en Keysight 3497A datainsamlingsenhet och LabVIEW-programvara. Trådens resistans och tillförd elektrisk effekt (=bortförd värmeeffekt) beräknades. Trådens temperatur bestämdes från resistansen med hjälp av kalibrerade data. För givna värden på  lufthastighet och lufttemperatur justerades den variabla spänningskällan manuellt så att önskad trådtemperatur erhölls för varje mätfall. På detta sätt skapades en tabell med mätdata för olika hastigheter, olika trådtemperaturer och lufttemperaturer. Dessa data kan användas för att studera olika driftfall för en varmtrådsanemometer.</concept></collMode>
        <collMode xml:lang="en">Physical measurements and tests<concept vocab="DDI Mode of Collection" vocabURI="https://vocabularies.cessda.eu/v2/vocabularies/ModeOfCollection/5.0.0?languageVersion=en-5.0.0">Physical measurements and tests</concept></collMode>
        <collMode xml:lang="sv">Fysiska mätningar och tester<concept vocab="DDI Mode of Collection" vocabURI="https://vocabularies.cessda.eu/v2/vocabularies/ModeOfCollection/5.0.0?languageVersion=sv-5.0.0">Fysiska mätningar och tester</concept></collMode>
      </dataColl>
    </method>
    <dataAccs>
      <useStmt>
        <restrctn xml:lang="en">Access to data through SND. Data are freely accessible.</restrctn>
        <restrctn xml:lang="sv">Åtkomst till data via SND. Data är fritt tillgängliga.</restrctn>
        <conditions elementVersion="info:eu-repo-Access-Terms vocabulary">openAccess</conditions>
      </useStmt>
    </dataAccs>
    <othrStdyMat>
      <relPubl />
    </othrStdyMat>
  </stdyDscr>
</codeBook>